Two defects in the panel as committed, both found by checking the code against
the authored data rather than by a test.
The authored row template is a Type-3 generic container, which resolves through
DatWidgetFactory's fallback arm to UiDatElement — whose constructor sets
ClickThrough = true ("generic decoration; behavioral widgets opt back in").
Binding OnClick without clearing that compiles, reads correctly, and produces a
list in which nothing can be selected: every click sails past the row. The
skills page had already met this and left the precedent; I did not follow it.
And there was no selection highlight at all, so even once clicking worked the
player could not tell which row the detail pane was describing. UiTemplateListBox
has no selection mechanism of its own, so the page opts in directly and
re-PAINTS the highlight after a rebuild — a rebuild discards the row objects, so
remembering the selection is not enough to keep it visible.
The tests for both initially passed while the bugs were live, because the
fixture's row root was a UiPanel and its text started white. A UiPanel is not
click-through, so the first test was vacuous; white-on-white made the highlight
unobservable. The fixture now builds the same UiDatElement production does and
authors a non-white colour. This is the third time this campaign a fixture that
did not match the real widget hid a real defect.
Live mount confirmed against the installed dats in this session's client run:
"[UI] retail journal panel from LayoutDesc importer (0x2100006E slot
0x10000559)" with no bind failure.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
The quest log is on screen. Rows come from the live tracker joined to the
authored catalog, the Status column runs QT4's port of FillProgressString, and
the detail pane shows contact, locations, description and the other timer.
Two things measured rather than assumed, each now pinned by an installed-DAT
test rather than left to the commit message:
The tab pairing is read from the authored 0x2E table, not inferred from
x-order — the FA campaign had to correct exactly that mistake, and Contracts
turns out to be the authored DEFAULT tab (0x32 = True), so opening on the
wrong one would have looked like an empty panel.
The open path needed no keybind at all. Toolbar button 0x1000055A authors
0x10000029 = 0x19 and has been sitting in ToolbarController.PanelButtonIds
since the toolbar was ported — it just had no panel behind it, so clicking it
did nothing. Registering slot 25 finished a wiring that was already
three-quarters present.
The list rebuild is revision-gated while the repeat countdown is not: nothing
on the wire changes as a cooldown runs down, so a rebuild-gated timer would
freeze on screen, and a per-frame rebuild would reset the player's scroll under
them. Both directions have a test.
Deliberately inert: the Abandon button (retail's abandon path is a
contract-registry command this campaign did not port — authored and visible,
but wiring a no-op handler would look responsive and lie), and the Journal
notes and Page List tabs, which are their own feature.
Campaign QT slices 5 and 6 of 6 — code-complete, connected gate owed.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>